Bridging system

Ceiling system 102

System Metal system to bridge large span
suitable for Flexible ceiling designs, individual applications
Characteristic Concealed to incorporate other ceiling systems

Components comply with the valid DIN-EN standards.

deflection DP 102/2,00 mmly= 195,7 cm4, Wy= 32,6 cm³, G = 7,2 kg/m
module distance „e“Meter0,901,201,501,80
ceiling loadkN/m²7,55 6,91 6,43 5,78 4,997,10 6,43 5,97 5,33 4,586,73 6,07 5,95 4,99 4,286,44 5,78 5,33 4,75 4,04
width between support „L“ A* Meter
B* Meter
7,55 6,91 6,43 5,78 4,99
6,03 5,97 5,40 5,01 4,51
7,10 6,43 5,97 5,33 4,58
5,17 4,80 4,54 4,17 3,72
6,73 6,07 5,95 4,99 4,28
4,97 4,60 4,33 3,97 3,53
6,44 5,78 5,33 4,75 4,04
4,80 4,43 4,41 3,81 3,38
deflection DP 102/3,00 mmly= 337,5 cm4, Wy= 48,2 cm³, G = 10,6 kg/m
module distance „e“Meter0,901,201,501,80
ceiling loadkN/m²7,55 6,91 6,43 5,78 4,997,10 6,43 5,97 5,33 4,586,73 6,07 5,95 4,99 4,286,44 5,78 5,33 4,75 4,04
width between support „L“ A* Meter
B* Meter
8,72 8,04 7,54 6,81 5,92
6,03 5,97 5,40 5,01 4,51
8,24 7,54 7,02 6,30 5,45
5,78 5,40 5,12 4,73 4,23
7,86 7,14 6,63 5,92 5,09
5,58 5,19 4,91 4,51 4,03
7,54 6,81 6,30 5,62 4,82
5,40 5,01 4,73 4,33 3,85

*A: in compliance with a permissible deflection of max. L/500
*B: in compliance with a permissible deflection of max. 4 mm